with your particular business in mind. The battery lifecycle reset becomes an available menu option on the front panel of the unit when (temporarily) running the non-EMC upgraded code. Replication Configuration It seems that many thousands of X1 customers may be stranded on XIOS 4.x software unable to take advantage of the software enhancements (however minor) in XIOS 6.0 and future versions. Dell will be marketing a new product to the marketplace to replace designated EMC EOSL systems. The SCs must have at least one UPS, reporting a good status, and known firmware, with 70% charge, to one SC, or it will refuse to boot the array up. Or they might offer more services that are better for your company. Obviously, VMAX supports mainframe (z/Series) and AS400 (i/Series), which XtremIO will never do. i upgraded the UPS 5p 1550i to the version 02.14.0026 and i connected to it through USB but i could not find any counter about battery life time, would you please explain more specifically about this parameter? 100% free GCP-GCX braindumps demo before buy. Let us extend the life of your hardware and make you a budget hero! This claims to have reduced latency by a factor of 5x. EMC XtremIO is a storage array enterprise created to work with flash . The system is content-aware where the data is laid out uniformly across all SSDs using the unique fingerprint of the incoming data. We take care of all of the technical details to accelerate In terms of software, there are enhancements to compression, which increases the savings ratio from (typically) 4:1 to 5:1. With the Dell EMC XtremIO and VMAX platforms, customers are asked to settle for two of these three. For example, you bought a single X2 X-Brick with 36 drives, you now want to scale UP (a new feature to X2, in X1 you could only scale out and now you can either scale up, out or both), you simply add another 6 drives, the procedure is fully non-disruptive. It further erodes the investment protection of XtremIOs Brick-based architecture by limiting access to software innovation to an install base that has tolerated a stand-still on hardware advances for the past two years. tagor villas ritz carlton, abama; daredevil main villains xtremio x2 end of life. Combined with the two year hiatus on new XtremIO hardware introductions, you should pause and ask Dell EMC if they are truly committed to XtremIO. The architecture appears to be so different that the XIOS 6.0 software may not even work on the previous-generation X1. It also targets organizations with large VDI deployments. program for Dell EMC customers who are seeking a modern storage ownership experience. Dell EMC Unity Cloud Edition is full-featured software-dened storage capabilities deployed in the Cloud. Check out this post, in which I discuss XDP changes, specifically in the comments, where the XDP groups are explained. [12] These distributed (across different controllers) software modules handle each individual I/O operation, which traverses the cluster. Dell EMC XtremIO X2 maintenance and support are required to ensure that the system continues to deliver optimum peak performance without any errors. PROCESSING PRACTICE: CPU & SYSTEM ARCHITECTURE, EMC close to buying XtremIO for $400-$450m, Traditional array all-flash retrofits knock XtremIO off top sales rung, Dell EMC Introduces New All-Flash Storage Systems to help Customers Modernize Their Data Centres and Transform IT, Garbage Collection #008 Chris Travels Commvault, NetApp and SFD14, Dell EMC Presents High-End Systems at Storage Field Day 14. So, upgrade your failed UPS to the current version, then make use of the battery lifecycle reset option to clear that countdown. Similarly, if you start with VMAX 450F V-Brick, you scale with 450F V-Bricks. Their install tool does perform some level of validation. NBD coverage includes helpdesk, onsite, call-homemonitoring, and partsreplacement. XtremIO was touted as the fastest selling all-flash array and number 1 in the all-flash market, based on EMC figures. . XtremIO X2 has addressed some of the shortcomings of the first platform. So there you have it, a poorly designed UPS timebomb can take your entire storage array down. The hardware upgrades are just point bumps to each product line, but nothing that actually changes the game. Dell EMC XtremIO is a purpose-built all-flash array that provides consistent high performance with low latency; unmatched storage efficiency with inline, all-the-time data services; rich application integrated copy services; and unprecedented management simplicity. The architecture appears to be so different that the XIOS 6.0 software may not even work on the previous-generation X1. to ensure that the system continues to deliver optimum peak performance IO path on X2 is completely new. X2-SD-BASE-ELA. As ever, this is the challenge, how to remain competitive in a market that is stagnant or even shrinking. You can take an //X for a spin, compare it head-to-head with the latest generation VMAX or XtremIO, and experience the difference for yourself! Industry: Insurance (except health) Industry. No NVMe support. Advisories. You can find the passwords to both on my page here. Copyright (c) 2009-2019 Post #6381 Chris M Evans, first published onhttps://www.architecting.it/blog, do not reproduce without permission. . With around only $25m in investment at acquisition, XtremIO represented a great payday for the investors. XtremIO is an all-flash storage array, designed from the ground up to unlock flash's full performance and deliver array-based capabilities leveraging unique characteristics of SSDs, based flash media. You also get more for your money. Data reduction remains limited by metadata. With the Pure FlashArray, customers can expand capacity (by adding Flash Modules) or performance (by upgrading controllers) independently, non-disruptively, and without these tradeoffs. Running WordPress behind an nginx reverse proxy on a different domain, Fix for EMC XtremIO complete failure due to Eaton BBU / UPS issues, https://community.spiceworks.com/topic/2156361-5p1000-weirdness. The XtremIO team claims that for data on XtremIO systems, 65% of all writes are for a block size of 8KB or less, so being able to reduce the overhead on small writes offers a big saving. Page XtremIO: End of Service Life. Thanks EMC! Gain in-depth understanding of how to leverage and optimize XtremIO features and capabilities in specic application areas. With X2, IOs are committed to NV-RAM vs. flash with X1. Need to know about the end of support status for XtremIo. Net-net, neither product refresh seems to solve the core issues that are driving customers to alternatives: At Pure we recently introduced FlashArray//X the new 100% NVMe version of FlashArray. 72 drive, ~3x larger than X1) X-Bricks or scale-out first to multiple X-Bricks and pay the controller tax per X-Brick just to expand capacity. The base unit of the XtremIO X2 line is the X-Brick. However, this has turned out not to be the case. You should now have a working UPS that reports as good to the XIO SC. We recommend you ask when Broadwell-based X-Bricks will be available, and whether a forklift upgrade will be required to get there. This may be why XtremIOs uptime stats remain unpublished. Youll want to SSH into it as xmsadmin, and then log in as the tech user. VMAX: Inefficient, complex, and expensive. From a development perspective, a lot of work has gone into the X2 release to address customer concerns. We offer Scaled Agile SAFe-Agilist dumps with 100% verified SAFe-Agilist practice exam questions and answers. . Seriously, EMCs fix is to just replace the entire unit any time the batteries need replacement. Update guide (ignore the part about DO NOT DOWNGRADE lol): https://www.ispcolohost.com/publicshare/Eaton_setUPS_5P_firmware_upgrade__rev_03-637.pdf, https://www.ispcolohost.com/publicshare/setups-win-2_5_0872.zip. Summed up in one word, this announcement feels incremental. [3], The company was acquired by EMC Corporation in May, 2012 for US$430 million, while the technology was still in development. Dell discontinuing support for your equipment doesnt imply it needs to be replaced. OEMs specialize in their equipment, but TPM programs focus on the needs of your company. Dell EMC XtremIO 4.0. Plus, the technicians who will be repairing your computer are experts in this field. [8], XtremIO reached $1 billion in sales in 2015, expanded the capacity of the product and introduced efficient copy data management at the storage layer (iCDM), among other incremental improvements. Memory on each controller in an X-brick is proportional(ish) to drive size, with X2-R having 1TB per controller and X2-S 384GB per controller. You need fast connections with fast protocols (NVMe) combined with global flash management to get to the next level of performance, density, and efficiency. Thank you !!. If it is not charged to at least 70%, the XIO will still refuse to boot, so that's fun. The architecture is based on closely coupled scale-out nodes called X-Bricks, connected by a 40Gb/s InfiniBand switch when 2 or more nodes are in a configuration. At a high-level, Dell EMC has refreshed and released two potentially overlapping products, and we applaud them for clarifying what each is for: VMAX for tier 1 workloads and consolidation, and XtremIO for point VDI and snapshot heavy environments like test & development (test/dev). The best option is to work with TPM. While the Dell EMC website has continued to market XtremIO as a highly-available architecture, we have heard many customer stories of upgrade challenges, downtime, and basic resiliency issues with XtremIO in the past. Learn how Top Gun provides the right support to help you keep, fine-tune and maintain your End of Life EMC systems. However, whether your array is down due to battery failure, or battery lifecycle counter reaching zero, you still have extra ridiculous steps to perform. The XtremIO platform is based on a multicontroller, N-way active model, in which the storage array scales to the number of available controllers (eight, as of this writing). Getting to VMAX 950F is a forklift upgrade if you want to expand performance or capacity. If youre lucky enough to be on the same 02.08.0016 version that I am, heres the link I found it at: https://www.touslesdrivers.com/index.php?v_page=23&v_code=49143&v_langue=en, The file name is: Eaton_5P_LVHV11_E0_V02.08.0016_TL00.zip, Heres my local copy from the above site but obviously you should try to get it from Eaton direct as I wont vouch for it: Eaton_5P_LVHV11_E0_V02.08.0016_TL00. Retrofit complexity abounds on VMAX All-Flash. Its also striking that these releases left the software behind. So lots of extra redundancy (like battery backup and dual nodes) was put into each X-Brick configuration. Choose your product, and then scroll down to the Service Life In 2017, buying an AFA without full NVMe support (or non-disruptive upgradability to full NVMe) is like throwing away your investment. Still NOT Evergreen: Future proofing and forklift upgrades remain a costly challenge on both XtremIO and VMAX. Different clusters can be managed within the same IT interface, however.[10]. For those interested in checking out our deeper evaluation, please read on. All the remaining characteristics (cores, connectivity) are the same but increased over X1 (50% more cores, twice the memory and support for 16Gb FC). [6][9], The XtremIO X2 line was introduced in May, 2017. I had the pleasant experience of both UPSs doing this within four hours of each other, so an XtremIO array running production traffic decided to just shut itself down in the middle of the day to protect me from data loss ROFL. The first XtremIO products (now renamed X1) were released to general availability in November 2013. Maple Grove, MN 55369
Accounting for dual-parity RAID overhead, this guarantee equates to ~5.3:1 total reduction on VMAX All-Flash and ~4.5:1 total reduction on XtremIO, based on stated usable physical capacity. Dell continues to offer post-warranty support for EMC End of Life hardware, but Third-Party Maintenance (TPM) is available for most OEM equipment that is EOL. If you dont have a lot of extra money to spend on upgrades, you can still use your existing hardware with the help of TPM. X2 will lag behind with its use of Haswell CPUs. Oct 2018 - Present4 years 1 month. But how will you deal with technical difficulties or breakdowns? The X2-S model uses smaller drives (400GB), so scales from 7.2TB to a maximum of 28.8TB per X-Brick. diffstat for arp-scan-1.8.1 arp-scan-1.8.4 ChangeLog | 142 INSTALL | 5 Makefile.in | 621 ++- NEWS | 40 TODO | 46 aclocal.m4 | 357 + arp-fingerprint | 58 arp-scan.1 . Our company have 2 deployments (1 single and 1 double X-brick) and uses this technology since 2015. You saved us a LOT of time !!. Different Brick models are NOT mixable / upgradable to other Brick models. https://community.spiceworks.com/topic/2105650-eaton-5p-5px-battery-countdown VMAX 250F/950F models employ 7.68TB and 15.36TB SSDs, Intel Broadwell CPUs, and 12Gb/s SAS-3 back-end shelves, whereas the VMAX 450F/850F models, which GAd just over a year ago, remain stuck on lower capacity SSDs, older CPUs, and 6Gb/s SAS-2 back-end shelves. Wait for it to charge, and then finally your first storage controller should come back online. And, not only is it available as an Evergreen upgrade to existing FlashArray customers, but also as an Evergreen on-ramp via our new NVMe NOW! If you are fixing your computer hardware yourself, you may not have access to the same parts that the manufacturer uses. Comments are always welcome; please read ourComments Policy. You saved us today man. Best Regards [12], The full-mesh RDMA network running on Infiniband maintains a consistent path length to each data block, which in turn provides the same latency. Below you can see a demo of how the new scaling-up feature will work When a manufacturer stops supporting a product, the equipment is not suddenly useless. Theres more. We deliver Mission Critical support, sale and consultation of refurbished IT hardware. If you keep your equipment, you will have to go without help from the original equipment manufacturer. Its easy to overlook or lose track of EOSL dates. Article Number: 497394: Article Version: 4: Article Type: How To: XtremIO HW Gen1,XtremIO HW Gen2 400GB,XtremIO HW Gen2 400GB Encrypt Capbl,XtremIO HW Gen2 400GB Encrypt Disable,XtremIO HW Gen2 400GB Exp Encrypt Disable,XtremIO HW Gen2 400GB Expandable,XtremIO HW Gen2 . Dell End of Life (EOL) means that Dell will no longer sell the hardware for that system, market, or update equipment after a certain date. Oh yes, you know the drill, EMC (now Dell/EMC) never overlooks a chance to create a dependency from a multi-hundred-thousand dollar disk array on a $1000 battery backup, or a $16 lead acid battery for that matter. Compression is not always-on; it must be configured manually on a per group level, Expansions require careful choice between scaling-out or scaling-up at each upgrade period. In comparison, the Pure FlashArray//M has proven, measured 6 9s across our install base now coming up on two years, and its inclusive of maintenance and upgrades. *Inclusion in the EOSL library does not guarantee Park Place can support that specific device. Leading a global group (Israel, US, China, Russia) of 100 software developers with 6 group managers. Fill out the form and well schedule a meeting with a NorthSmart expert or call us now, Home EMC XTREMIO X2-S INFINIBAND SWITCH. time-consuming. X2 systems use an NV-RAM drive and super-capacitor. XtremIO X2. From a hardware perspective, there are now two configurations, the X2-S and X2-R. If you have any related links of interest, please feel free to add them as a comment for consideration. XtremIO: Apparently unreliable for Tier 1 workloads. As long as there arent any glaring issues with the hardware or problems with its place in your companys infrastructure, you can keep using it for longer by using TPM. STORAGE. Easy to use user interface that requires minimum training. So although theres overlap, there are unique features only VMAX offers. Extend your storage and server equipment life with Top Gun support. RAID 5 vs. And those differences create a sharp contrast for customers. Where do I find End of Service Life Dates for XtremIO Products? Touring the world with friends one mile and pub at a time; is heavenly gondola open today. RAID 6 choice has to be decided at time of purchase, Data-at-Rest Encryption needs to be configured before the VMAX ships, otherwise it requires a system wipe to enable encryption, BIN files are still present, just hidden from you via out-of-factory configuration. xtremio x2 xios 6.0 x2 x1 x1 xios 2.4 3.0 emc . was created with 10 XtremIO volumes over an empty array. This will drastically raise maintenance and support rates. In comparison, the Pure FlashArray//X uses Intel Broadwell CPUs and we have a proven history of introducing newer Intel CPU-based controllers every 12 to 18 months. Its interesting to note that following a visit from Joe Tucci, two VMware execs visited the company shortly before it was acquired. And, while compression was introduced on VMAX All-Flash last fall with the use of bolt-on compression I/O modules, VMAX All-Flash metadata was simply not designed for data reduction. EOL & EOSL DATES. Verwalten Sie mit der Unternehmensverwaltung Ihre Dell EMC Seiten, Produkte und produktspezifischen Kontakte. Now that we know how important the UPS is to XIO even functioning, that seems a step crazier than necessary, because if youre in the process of replacing one and simply bump the serial cord out of the other, the array will go to fully degraded and shut down. Seriously they should be sued. Linux Kernel, Docker containers, HW qualification, non-disruptive upgrade, Protocols (SCSI, NVMe over fabric) E2E . IT Infrastructure Management How to Stay on Budget & Innovate. Director, software development. I suspect both Eaton UPSs were manufactured four hours apart from one another, or perhaps clock drift just left us at the point we arrived at, but seriously, both reached battery life cycle expiry four hours apart, went to degraded state, and the array then shut both storage controllers in the XBrick down safely to protect me from myself. Hardware density was increased; the X2 features more processing cores and a 4U controller head instead of the old 6U profile. 1 Cybersecurity requirements: PowerStoreOS 2.0 or higher. delltechnologies.com//storage/xtremio-all-flash, "Compare XtremIO vs. And, while we compete and win plenty against VMAX All-Flash, we have yet to see customers turning on VMAX All-Flash compression. Eventually, your OEM will announce EOL on that line of equipment. By extending the life of your We provide implementation services to help you get up and running quickly on In contrast, FlashArray//X offers 100% NVMe for mainstream Tier 1 deployments today. With the recent termination of DSSD, many had wondered how VMAX (and XtremIO) might possibly leverage Dell EMCs acquired NVMe knowhow and proprietary technology maybe in the future seems to be the response. Signup for our newsletter to get notified about sales and new products. EMC certainly needed to get their money back. 5500 Cottonwood Lane SE, Ste. Add monitoring EOSL for EMC to your checklist of things that Top Gun Technology can automate for you. without any errors. The next-generation platform, XtremIO X2, builds upon unique features of XtremIO . Greer, SC 29650
What does the future look like for the all-flash platform? Hardening storage products is hard, time-consuming work. Up to 8 X-Bricks can be combined into a single cluster with a raw capacity of up to 1.1 PB, which the company claims is an effective capacity of 5.5 PB due to the 6:1 data efficiency ratio achieved through what it calls intelligent data packing.[10] X-Brick interconnectivity is achieved using 40Gbps InfiniBand. Were not done yet. The best part about this is that the batteries had simply reached a pre-determined time limit on when Eaton believes they should no longer be relied on, they hadnt failed a self test. View more EOSL dates. The top reviewer of Dell SC Series writes "The performance was staggering and more than . Eaton designed this pile of crap rack mount UPS to require removal from the rack to replace the batteries; ROFL. While XtremIO was quick to hit $1 billion in sales and has added several new features like iCDM, there hasn't been a hardware leap in several years.XtremIO X2 now brings to bear an all-new custom chassis and core software update, XIOS 6.0. EMC VMAX 450F and 850F go EOSL October 31, 2023. NorthSmart can provide support for X2-SD-SWITCH-FD hardware after the end of official support date, saving you money in the process, As a If your products are at the end of their life or support life, you may feel like you are stuck. In addition, a TGT Product Manager will help guide you through the process. United States. Both product lines are still not Evergreen. They have access to trusted parts that will work with your equipment. [1] The current version is the X2 line. From a hardware perspective, there are now two configurations, the X2-S and X2-R. XtremIO X2 Dimensions. That being the case, you need to ensure you have the version it is currently running before starting this process, as youll need to downgrade back to that version afterward. third-party data center hardware maintenance company, Converged Technology Extension for VMAX Storage 400K, VxRack System Flex with Dell 13G PowerEdge Nodes. has announced EOSL on all. Leaving you to focus on running Dell SC Series is rated 8.6, while Dell XtremIO is rated 7.0. [4] Considered a gamble by some experts, the acquisition was soon followed by additional merger activity in the flash market. *Please select an option from the dropdown menu, Primenet | All Rights Reserved | Registered in England and Wales 03139999, Dell EMC XtremIO KYLIN Server 256GB D25-400, Unit 8 Arlington Court, Whittle Way, , Stevenage, 7 Best Practices for Vulnerability Assessment & Management, Everything you need to know about a Data Breach, Why end of service life doesn't mean the end, How to reduce IT infrastructure and operations costs, How IT outsourcing helps to scale your technical team.